RE: Roof Diaphragm / Ridge Vent

[Subject Prev][Subject Next][Thread Prev][Thread Next]
Run the roof sheathing to the top of the ridge to connect the diaphragm.  The required opening area can generally be accommodated by drilling a series of holes through the roof sheathing below the vent.