Scratch what I said, you have a different type of wall.  

However, if I were you, I'd use temperature steel both ways.

Hector

> -----Original Message-----
> From:	Mark D. Baker [SMTP:shake4bake(--nospam--at)earthlink.net]
> Sent:	Wednesday, June 17, 1998 4:39 PM
> To:	seaoc
> Subject:	temp steel
> 
> Regarding more info:
> 
> This is an 8' high shotcrete wall, 12" thick set on conc. caissons @
> 5'
> o.c.
> Wall pilaster steel is within the 12" wall thickness @ 5' o.c. (there
> is
> no concrete projection beyond face of wall at pilaster locations)
> The #4 @ 18" flexural steel is horiz., spanning between pilasters, the
> #4 @ 9" temp. steel is vertical.
> The wall is 100' long.
> 
> Mark
> 
>