I typically use the 3" sand barrier vapor barrier only on commercial
projects in which the slab-on-grade is poured sep. from the grade beams
and/or spread footings.  Most residences in this area (Louisiana) are
monolithicly poured stiffened rib foundations, primarily
post-tensioned.  I also do not trust the quality of the residential home
builders around here.  

I never use the 3" sand barrier in monolithic slabs or post-tensioned
slabs.  

Brian K. Smith, P.E.