When you use SRSS load combination of STAAD-III, all the compression  members are designed as tesile members in design mode.
For the above problem, I e-mailed reiusa.com receiving mail that " above design error happen since Srss combination always give positive force values". It seems like they did not fixed or deleted Srss command yet.  
  
           young ki Kim (P.E)


>>The method of combining modal results in
>>all of the response spectrum values being reported as positive values thus
>>making it meaningless to draw a moment diagram.
>Not entirely meaningless. Although reported positive the combination
>actually has no sign since it changes throughout the event. You can't
>calculate an external load at a node by summing the internal loads of the
>attached elements, but there are a couple of things you can do, if you
>really need the information.
>
>You can get external loads for the member in question for each mode, then
>combine the modal loads with the same methodology used for the stress
>combination (CQC, SRSS, whatever). These loads are equivalent nodal
>forces to the distributed dynamic loads, so your moment diagram will be a
>piecewise linear approximation to the actual moment diagram.
>
>Another method useful for connection loading is to write off the combined
>modal displacements and impose them as displacement constraints in a
>static run along with the original displacement constraints. The
>resulting load set is again equivalent to the structure dynamic loading
>(since it produces the same displacement), only with the member internal
>load signs preserved. If you use any sort of reduced analysis you don't
>need to use every calculated displacement, only the master DOF
>displacements from the expanded modal solution. You can add gravity and
>live loading to the problem however you like.
>
>The pitfall here is that the combined modal solution is always an
>envelope--any single stress, load or displacement response is the maximum
>expected during the event, but the individual maximums aren't
>simultaneous. The structure will probably never assume the shape
>determined by the combined modal displacements, so a moment diagram
>corresponding to the displaced structure will be an envelope of all the
>maximum internal moments, not a moment diagram at some instant in time.
>
>Christopher Wright P.E.    |"They couldn't hit an elephant from
>chrisw(--nospam--at)skypoint.com        | this distance"   (last words of Gen.
>___________________________| John Sedgwick, Spotsylvania 1864)
>http://www.skypoint.com/~chrisw
>
>
>
>
>******* ****** ******* ******** ******* ******* ******* ***
>*   This email was sent to you via Structural Engineers
>*   Association of Southern California (SEAOSC) server. To
>*   subscribe (no fee) to the list, send email to
>*   admin(--nospam--at)seaint.org and in the body of the message type
>*   "join seaint" (no quotes). To Unsubscribe, send email
>*   to admin(--nospam--at)seaint.org and in the body of the message
>*   type "leave seaint" (no quotes). For questions, send
>*   email to seaint-ad(--nospam--at)seaint.org. Remember, any email you
>*   send to the list is public domain and may be re-posted
>*   without your permission. Make sure you visit our web
>*   site at: http://www.seaint.org
>******* ****** ****** ****** ******* ****** ****** ********