Re: Slender concrete columns

[Subject Prev][Subject Next][Thread Prev][Thread Next]
Greetings,

According to ACI 318-95 eq. 10-8, a column is slender only if kl/r>34 since
M1 and M2 are zero, in your case.
Therefore eq. 10-2 for designing columns is applicable.

According to British Standards BS8110. They have 2 equations
N=0.4*fcu+0.75*As*fy
&
N=0.35*fcu+0.67*As*fy

I hope the above answers your question
Regards,

Hasan
-----Original Message-----
From: BDWOLF123(--nospam--at)aol.com <BDWOLF123(--nospam--at)aol.com>
To: seaint(--nospam--at)seaint.org <seaint(--nospam--at)seaint.org>
Date: ÇáÇÑÈÚÇÁ, íæäíæ 23, 1999 09:53 PM
Subject: Slender concrete columns


>Anyone out there know how to deal with a concrete column with axial load
only
>with a kl/r ratio larger than 22?
>
>Andrew Arnold
>Arnold Engineering
>
>