RE: 125' long steel truss, connection question

[Subject Prev][Subject Next][Thread Prev][Thread Next]
Another design reference you may try is Hollow Structural Sections
Connection Manual by AISC.  It was published in 1997.

Ralph Benson
Huitt-Zollars, Inc.

 -----Original Message-----
From: Simon Solorio [SMTP:simon(--nospam--at)solorio.com]
Sent: Wednesday, June 23, 1999 7:03 PM
To: seaint
Subject: 125' long steel truss, connection question


I'm designing a 125' long steel truss, a section view of the truss is a
triangle. The top chords (2 top chords) are pipes and the bottom chord (1
bottom chord) is also a pipe. The web members are pipes.
Questions;
1. the top and bottom chords are going to be a continuous pipe, so when I
analyse the truss should I assume the connection at the node
intersections
(at the chords only) fixed or should I analyse it assuming the the chords
are
pinned between each node of the truss?

2. the pipe web members are going to welded to the pipe chord members
with
fillet welds, where can i find information on how much fixity i should
design
this connection.

The architect does not want to see any plates, so I think if the
connection
of the web to chord is all welded then the connection has some fixity.
I've check the truss with all the members fixed and the truss with all
the
members pinned but i think, with the fillet weld connections, the percent
of
fixity is in-between a fixed and hinged connection. The reference books I
have show a welded connection like the one I need to design and seem to
assume the connections are pinned.

Thank you in advance

Simon Solorio, P.E.