> I have designed many communication towers that ranged from 100 ft to 1900
> ft tall and have always used 1/16" oversize on the bolt holes.  In some
> heavy structural cases where member mill tolerance is suspect and the
> member sizes are extremely heavy, I have taken an exception to the 1/16"
> and utilized 1/8" oversize.  Your problem is most likely a combination of
> base level, since the misalignment becomes exaggerated the higher you get
> if the base is not level, and fabrication tolerances.
> 
> Clint