Need a book? Engineering books recommendations...

Return to index: [Subject] [Thread] [Date] [Author]

FWD: MWFR for Multiple Gable Roof

[Subject Prev][Subject Next][Thread Prev][Thread Next]
From: Jeff Fisher<jfisher(--nospam--at)clarknexsen.com>
To: seaint(--nospam--at)seaint.org
Subject :  MWFR for Multiple Gable Roof

I am working on a BOCA Building Code design of a large industrial building 
with a multiple gable roof ( ^^^ ).  I am trying to determine the 
main-wind-forces on the gables to determine the total lateral loads.  As far 
as I can tell BOCA doesn't provide much guidance for this situation.  ASCE 
7-95 addresses this situation for components and cladding but not for MWFR.  
Initially, I thought I should use the external pressures for a single gable 
roof and multiply that lateral load by 3 (3 gable roof) to get the total 
lateral load on the roof, but that seems a bit conservative.

Details of roof: the roof consists of three gables in a row - starting at the 
edge of the building going 30 feet horizontally into the building is the 
first ridge 17.5 feet above the edge (eave), going another 30 feet 
horizontally into the building is the first valley at the same level as the 
eave, going another 30 feet horizontally into the building is the second 
ridge 17.5 feet above the valley, going another 30 feet horizontally into the 
building is the second valley, going another 30 feet horizontally into the 
building is the third ridge, going another 30 feet horizontally into the 
building is the other edge of the building (other eave).

If anyone can provide any information for me as far as how to analyze this 
structure or where I can find information on how to analyze this structure, I 
would greatly appreciate it.  Thanks...
 