As indicated by Ed Workman, the analysis must allow for catenary action
either through cable elements (FEA) or analytical methodology. Proprietary
tower software will/should assume a catenary for the cable (for example, see
http://www.powline.com/products/mast.html ) and will also assume pinned
connections at each end. However, the base of the tower needs to be defined
as pinned/fixed and designed appropriately. Depending upon the geometry of
the tower, aerodynamic enhancement of loads may also need to be assessed.

James Cohen
James Cohen Consulting, P.C.
PO Box 130
Pennington, NJ 08534
Tel: (609) 730-0510
Fax: (609) 730-0511
Website: http://expertpages.com/~jccpc