Re: drift calculation, 1997 UBC using ASD

[Subject Prev][Subject Next][Thread Prev][Thread Next]
In a message dated 11/10/99 3:10:55 PM Pacific Standard Time, 
rjbossi(--nospam--at)sonic.net writes:

<< Alex:
 My code (1998 CBC, first printing) says:": ... the load combiations of  
1612.2
 shall be used."  1612.2 load combinations are USD and do not contain a 1.4
 factor.  ie Eq 12-5 or 12-6.
 
 Bob Bossi
  >>
 First errata to UBC97 changes the reference to 1612.2 to 1612.3, which means 
E/1.4 for drift calculations using ASD. It may not be the intention of the 
author, but there is also the Rho factor which got misinterpreted. You Loose 
some, you win some.