Return to index: [Subject] [Thread] [Date] [Author]

RE: Overturning check

[Subject Prev][Subject Next][Thread Prev][Thread Next]
Agreed. Probably for Seismic 1.0 is okay. I'm sorry that I didn't get that
fact.

My experience with OT checks is for tall equipment (e.g. process towers,
etc.) in petrochemical facilities where wind load controls.

Thanks.

-----Original Message-----
From: Khosrownia, Ghassem SPK [mailto:GKhosrownia(--nospam--at)spk.usace.army.mil]
Sent: Wednesday, February 02, 2000 10:39 AM
To: 'seaint(--nospam--at)seaint.org'
Subject: RE: Overturning check


Bill,

Where do you get the safety factor from?