According to Steel Joist Institute Standard Load Table, adopted 10/1/74 a
32LH07 spanning 60' can take a total safe uniform load of 262 plf. The live
load to cause deflection of L/360 = 133 plf.

Randy Russ
Russ Engineering Group, Inc.
Baton Rouge, La.

-----Original Message-----
From: Brian K. Smith <smitheng(--nospam--at)dos.net>
To: seaint(--nospam--at)seaint.org <seaint(--nospam--at)seaint.org>
Date: Thursday, April 27, 2000 10:46 AM
Subject: RE: old joist


> Can anyone give me the allowable loads for '78 vintage 32LH07's, 60'
>span????  Also, did the SJI LH spec at that time require a minimum shear at
>midspan like they do with the K's now???
>
>
>Brian K. Smith, P.E.
>
>
>