RE: IBC, Rho Factors, 10/lw, and Influence of FEMA/NEHRP Folks

[Subject Prev][Subject Next][Thread Prev][Thread Next]
Dennis Wish wrote (to Ron Hamburger):
> Are you confirming that 10/Lw need not exceed 1.0 in wood
> framed structures with wood diaphragms as was the opinion
> of the SEAOC Blue Book committee?

At the recent IBC code hearings the following sentence was added to
Section 1617.2.2 of the International Building Code: "In light-frame
construction the value of the ratio of 10/lw need not be greater than
1.0."

- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -