Return to index: [Subject] [Thread] [Date] [Author]

Re: yield strength of A706 rebar

[Subject Prev][Subject Next][Thread Prev][Thread Next]
What is the specified ultimate strength for A706 ??

Is that also given as a minimum ??

jgkorff, pe

----- Original Message -----
From: "Brent Koch" <kochengr(--nospam--at)pacbell.net>
To: <seaint(--nospam--at)seaint.org>
Sent: Wednesday, June 21, 2000 12:37 PM
Subject: RE: yield strength of A706 rebar


> The specified minimum yield strength for A706 reinforcing steel is 60,000
> psi. This is the ONLY yield strength level covered by the A706
> specification. Thus by specifying A706 reinforcing the 60 ksi yield
strengh
> is automatic. Also, AFAIK, there is no such thing as A706 #3. The mills
roll
> this spec. in #4 and larger.
>
> Brent R. Koch, P.E.
> KOCH ENGINEERING, INC.
> Livermore, CA
> mailto:kochengr(--nospam--at)pacbell.net
>
>
> From: Dan Vines [mailto:dan(--nospam--at)willettengineering.com]
> Sent: Wednesday, June 21, 2000 09:37
> To: SEAINT (E-mail)
> Subject: yield strength of A706 rebar
>
>
> Is A706 (weldable) rebar available in gr60?
>
> Thanks
> Dan
>
> Sherman D. (Dan) Vines, EIT
> Willett Engineering Co., Inc.
> dan(--nospam--at)willettengineering.com
>
>