I have a project where the lateral system consists of moment frames located 
in the city of L.A. (frame required due to large expanses of glass). The roof 
is wood framed and in all other aspects I would use an ordinary moment frame, 
but there is a planter load over approximately 1/4 of the area of the roof 
with an added dead load of 150 psf over this area (Almost entirely over the 
frame lines).  The code for city of L.A. seems to allow an ordinary frame 
only for cases where dead load is less than 15 psf - so a special frame seems 
required.  Are there standard published data for cyclic test results for 
frames or do I need to have a mock up constructed?  
Also, in the design of ordinary frames, where the AISC provisions require 
designing for the maximum moment that can be delivered by the system, is the 
seismic part of the load based on UBC equation 30-4, 30-5, or 30-11 (section 
1630.2) 
Thanks 
Paul Franceschi S.E. 

******* ****** ******* ******** ******* ******* ******* *** 
*   Read list FAQ at: http://www.seaint.org/list_FAQ.asp 
*   This email was sent to you via Structural Engineers 
*   Association of Southern California (SEAOSC) server. To 
*   subscribe (no fee) to the list, send email to 
*   admin(--nospam--at)seaint.org and in the body of the message type 
*   "join seaint" (no quotes). To Unsubscribe, send email 
*   to admin(--nospam--at)seaint.org and in the body of the message 
*   type "leave seaint" (no quotes). For questions, send 
*   email to seaint-ad(--nospam--at)seaint.org. Remember, any email you 
*   send to the list is public domain and may be re-posted 
*   without your permission. Make sure you visit our web 
*   site at: http://www.seaint.org 
******* ****** ****** ****** ******* ****** ****** ********