RE: Nail Slip

[Subject Prev][Subject Next][Thread Prev][Thread Next]
The factor applied to this term also carries units of 1/length so that
the results work.  You will notice that this factor changes for SI.

- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
Michael Valley, P.E., S.E.                   E-mail: mtv(--nospam--at)skilling.com
Skilling Ward Magnusson Barkshire Inc.              Tel:(206)292-1200
1301 Fifth Ave, #3200,  Seattle  WA 98101-2699      Fax:        -1201

-----Original Message-----
From: Nels Roselund [mailto:n.roselund(--nospam--at)worldnet.att.net]
Sent: Monday, August 14, 2000 2:34 PM
To: seaint(--nospam--at)seaint.org
Subject: Nail Slip


I'm working with the UBC formula for deflection of a plywood sheathed
shear
wall in Section 23.223 of UBC Standard 23-2.

The deflection determined by the formula and each of the terms in the
equation for shear wall deflection have units of length except the
nail slip
term, which has units of length x length (h has units of inches, and
en --
according to Table 23-2-K has units of inches).

What am I missing?

Nels Roselund
Structural Engineer


******* ****** ******* ******** ******* ******* ******* *** 
*   Read list FAQ at: http://www.seaint.org/list_FAQ.asp 
*   This email was sent to you via Structural Engineers 
*   Association of Southern California (SEAOSC) server. To 
*   subscribe (no fee) to the list, send email to 
*   admin(--nospam--at)seaint.org and in the body of the message type 
*   "join seaint" (no quotes). To Unsubscribe, send email 
*   to admin(--nospam--at)seaint.org and in the body of the message 
*   type "leave seaint" (no quotes). For questions, send 
*   email to seaint-ad(--nospam--at)seaint.org. Remember, any email you 
*   send to the list is public domain and may be re-posted 
*   without your permission. Make sure you visit our web 
*   site at: http://www.seaint.org 
******* ****** ****** ****** ******* ****** ****** ********