this has been used for about 25 yrs. in So. Cal. Suggest you contact PCA
for specs. Basically we just spec. a "1 sack/cu. yd. mix" or sometimes
for less stringent applications such as no traffic a "1/2 sack/cu. yd.
mix". The aggregate is usually pea gravel max. size. I probably can find
a better spec. if necessary. I'll bet the Readymix Assoc. has a spec. 
One of the first uses of this type of backfill was for portions of the
Calif. Aqueduct around 21 ft. dia. pipe near Fresno, Ca. in about 1968.