Return to index: [Subject] [Thread] [Date] [Author]

Re: Lifting Devices

[Subject Prev][Subject Next][Thread Prev][Thread Next]
So far as I know, an old Navy standard is still good.  Load factor of 3 for
standing rigging & 6 for running rigging.

Fountain E. Conner, P.E.
Gulf Breeze, Fl. 32561

----------
> From: H Boge <HBOGE(--nospam--at)boge-boge.com>
> To: Seaint(--nospam--at)seaint.org
> Subject: Lifting Devices
> Date: Friday, March 30, 2001 10:56 AM
> 
> An industrial facility is asking us to review their lifting bales, hooks
and other lifting devices.
> 
> Please advise where I can find load factors for these types of elements.