It is important you to remind that this 1/2" gap, is
a "reference minimum", and according to the codes,
this is to be checked for the amplified elastic deformations.
Regarding this, look at the Blue Book, in the corresponding
chapter ( frames & infills ).

RL

-----Mensaje original-----
De: ijr <issajr(--nospam--at)yahoo.com>
Para: seaint(--nospam--at)seaint.org <seaint(--nospam--at)seaint.org>
Fecha: Sábado, 28 de Abril de 2001 03:19 a.m.
Asunto: Re: steel frame with masonry infills


>Alex
>
>You have the keywords in your post: "Seismic Zone 4" &
>"A school". And it is a school, man.  In US codes your
>are probably forced to do ductile design of such
>frames in such zones.
>
>If I were you I would elect not to attach any  infill
>to the frames, and I would utilize a conservative
>ductile frame design. Infills are terrible and I
>believe your specification is right on suggesting you
>leave a 1/2 "" gap.
>
>I am not sure you can call that "dual". "Dual" may be
>taken to mean "frames sway and shear walls deflect".
>Do you have this basic behavior with infill between
>columns?
>
>For a school I might as well go on add some braces or
>a serious ductile RC shearwall.
>
>Good luck
>IJR
>
>
>
>
>
>
>--- Nacionales Alex <acnacionales(--nospam--at)yahoo.com> wrote:
>> Hello.
>> I am the project engineer for the owner of a four
>> storey steel framed school building with 6" CHB
>> walls.
>>
>> The building is about 12M wide and 62M long and 14 M
>> tall.
>> The frame is a special moment resisting space frame
>> and we are in seismic zone 4. I have little design
>> experience in steel framed buildings but I believe
>> that a dual system would be more economical here
>> where
>> a load bearing 6" CHB wall could act as shear wall.
>>
>> The design specifies that the CHB be laid 1/2" from
>> the steel columns and shall have 1/2" thick styrofor
>> to fill the gap. I find this to be unnecessary. I am
>> aware that masonry infills specially where there are
>> low windows can interfere with the frame action as
>> observed in RC construction in the past earthquakes
>> but RC columns can be designed against this by
>> providing more shear reinforcement above the window
>> level, for steel columns its different because the
>> section is the same for one length so the design for
>> maximum shear at the base of the column should be
>> sufficient.
>>
>> I would appreciate some comments on this. Thanks.
>>
>> Alex C. Nacionales, C.E.
>>
>>
>> __________________________________________________
>> Do You Yahoo!?
>> Yahoo! Auctions - buy the things you want at great
>> prices
>> http://auctions.yahoo.com/
>>
>> ******* ***
>> *   Read list FAQ at:
>> http://www.seaint.org/list_FAQ.asp
>> *
>> *   This email was sent to you via Structural
>> Engineers
>> *   Association of Southern California (SEAOSC)
>> server. To
>> *   subscribe (no fee) or UnSubscribe, please go to:
>> *
>> *   http://www.seaint.org/sealist1.asp
>> *
>> *   Questions to seaint-ad(--nospam--at)seaint.org. Remember, any
>> email you
>> *   send to the list is public domain and may be
>> re-posted
>> *   without your permission. Make sure you visit our
>> web
>> *   site at: http://www.seaint.org
>> ********
>
>
>__________________________________________________
>Do You Yahoo!?
>Yahoo! Auctions - buy the things you want at great prices
>http://auctions.yahoo.com/
>
>*
>*   This email was sent to you via Structural Engineers
>*   Association of Southern California (SEAOSC) server. To
>*   subscribe (no fee) or UnSubscribe, please go to:
>*
>*   http://www.seaint.org/sealist1.asp
>*
>*   Questions to seaint-ad(--nospam--at)seaint.org. Remember, any email you
>*   send to the list is public domain and may be re-posted
>*   without your permission. Make sure you visit our web
>*   site at: http://www.seaint.org


* 
*   This email was sent to you via Structural Engineers 
*   Association of Southern California (SEAOSC) server. To 
*   subscribe (no fee) or UnSubscribe, please go to:
*
*   http://www.seaint.org/sealist1.asp
*
*   Questions to seaint-ad(--nospam--at)seaint.org. Remember, any email you 
*   send to the list is public domain and may be re-posted 
*   without your permission. Make sure you visit our web 
*   site at: http://www.seaint.org