Return to index: [Subject] [Thread] [Date] [Author]

RE: Salt Lateral Bin Pressures

[Subject Prev][Subject Next][Thread Prev][Thread Next]
Salt, dry, coarse - 40-55 pcf
Salt, dry,fine    70-80 pcf   angle of repose 25 deg.
 
K is unknown but I would use K=.3
 

Ronald Hill, P.E.
HILL Consulting Engineering
Birmingham, Alabama  USA
Phone: 205.823.4784
FAX: 205.823.4145
Email: ronhill(--nospam--at)hillce.com
Efax: 509.275.8095
http:\\www.hillce.com

-----Original Message-----
From: John Schenne [mailto:jschenne(--nospam--at)localnet.com]
Sent: Tuesday, May 22, 2001 6:41 PM
To: seaint(--nospam--at)seaint.org
Subject: Salt Lateral Bin Pressures

I am working on a salt storage building.  Anyone have a good reference for the lateral pressure exerted on a bin by a heaped mass of salt?
 
Thanks,
 
 
John Schenne