Return to index: [Subject] [Thread] [Date] [Author]

RE: Reduction of Snow Load?

[Subject Prev][Subject Next][Thread Prev][Thread Next]
No, snow load is different than live load and cannot be reduced because a member has a large tributary area.  UBC 1614 can be used to reduce the snow load based on the slope of the roof.
 

Scott M Haan P.E.
Plan Review Engineer
Building Safety Division http://www.muni.org/building
Development Services Department
Municipality of Anchorage
phone:907-343-8183  fax:907-249-7399
mailto:haansm(--nospam--at)ci.anchorage.ak.us

-----Original Message-----
From: ken kirkland [mailto:kenmail234(--nospam--at)yahoo.com]
Sent: Friday, June 22, 2001 11:35 AM
To: seaint(--nospam--at)seaint.org
Subject: Reduction of Snow Load?

 Can I use The UBC - Section 1607.5 to determine the reduction of snow load? 



Do You Yahoo!?
Get personalized email addresses from Yahoo! Mail - only $35 a year!
http://personal.mail.yahoo.com/