Re: ASD Weak Axis Bending of Rolled Channel

[Subject Prev][Subject Next][Thread Prev][Thread Next]
F2.1 would apply as long as the channel flanges meet the local bucking
criteria of section B5, otherwise you would apply F2.2.

Paul Feather
----- Original Message -----
From: "Les Rhinehart" <l_n_rhinehart(--nospam--at)email.com>
To: <seaint(--nospam--at)seaint.org>
Sent: Monday, June 25, 2001 3:11 PM
Subject: ASD Weak Axis Bending of Rolled Channel


> Does anyone knows if Fb=0.75Fy applies to a rolled channel ( C5x6.7 for
> example) bent about the weak axis?  AISC ASD F2.1 does not mention
channels
> as I read it.  RISA-3D uses F2.1 as applying to a channel.  Can anyone
shed
> some light on this.  I would appreciate any help.
>
> Thanks,
>
> Les Rhinehart
> VITOK Engineers, Inc.
> Louisville, KY
>
>
> *
> *   This email was sent to you via Structural Engineers
> *   Association of Southern California (SEAOSC) server. To
> *   subscribe (no fee) or UnSubscribe, please go to:
> *
> *   http://www.seaint.org/sealist1.asp
> *
> *   Questions to seaint-ad(--nospam--at)seaint.org. Remember, any email you
> *   send to the list is public domain and may be re-posted
> *   without your permission. Make sure you visit our web
> *   site at: http://www.seaint.org
>


* 
*   This email was sent to you via Structural Engineers 
*   Association of Southern California (SEAOSC) server. To 
*   subscribe (no fee) or UnSubscribe, please go to:
*
*   http://www.seaint.org/sealist1.asp
*
*   Questions to seaint-ad(--nospam--at)seaint.org. Remember, any email you 
*   send to the list is public domain and may be re-posted 
*   without your permission. Make sure you visit our web 
*   site at: http://www.seaint.org