Re: RESIDENTIAL: Wood Framing Tolerances for Plumbness

[Subject Prev][Subject Next][Thread Prev][Thread Next]
Bill

I am not aware of any specific requirements. I checked the NDS Appendix A,
Construction and Design Practices. Nothing shown there.

When I worked for PKS (Kiewit) in the early 1970's, I was on the engineering
crew (survey stuff also) and we plumbed at steel tower to within a 1/16 inch
at a height of 120 feet. I would expect that wood framed structures could be
held to this tight of a tolerance, but in general, I think something like
a 1/2 inch tolerance would be acceptable. The use of the structure and
loadings could also be factored in establishing the final tolerance.

For residential construction, I would check with the structural warranty
companies to see what their policy covers. My RWC policy says "walls which
are out of plumb in excess of 3/4 inch within a vertical measurement of
eight feet is a defect". I remember that when I worked for HBW that they
used the same requirement.

HTH

Bruce Pooley
Timber Design
3448 South Newland Court
Lakewood, CO 80227
303-989-8701



******* ****** ******* ******** ******* ******* ******* ***
*   Read list FAQ at: http://www.seaint.org/list_FAQ.asp
* 
*   This email was sent to you via Structural Engineers 
*   Association of Southern California (SEAOSC) server. To 
*   subscribe (no fee) or UnSubscribe, please go to:
*
*   http://www.seaint.org/sealist1.asp
*
*   Questions to seaint-ad(--nospam--at)seaint.org. Remember, any email you 
*   send to the list is public domain and may be re-posted 
*   without your permission. Make sure you visit our web 
*   site at: http://www.seaint.org 
******* ****** ****** ****** ******* ****** ****** ********