Keith,

I don't remember exactly what size the hardy frames were that had to get
removed, they we on a job another engineering firm designed and this
contractor had to remove them, he was questioning me when he saw them on a
job I designed.

I have no problem whatsoever with the claims made by simpson on the
performance of the strongwall. My beef is that I cannot use the strongwall
for a raised floor application because there is no ICBO approval-only
directly bolted to a foundation. I was concerned because Hardy has ICBO
approval for this -then this contractor told me bay area building department
made him switch out to a non-approved panels. He (the contractor) sugggested
that a simpson rep is whispering in the ears of inspectors.

-gerard

-----Original Message-----
From: Keith De Lapp [mailto:kdl(--nospam--at)directcon.net]
Sent: Friday, November 09, 2001 9:00 AM
To: seaint(--nospam--at)seaint.org
Subject: Re: Hardy Panels


My understanding of the Strongwall, is that since its performance under
testing has demonstrated good drift characteristics, the ICBO allows the
product to exceed the allowable shear wall aspect ratio.  I believe the
whole point of limiting the aspect ratio is, in effect controlling drift in
light of the limited test data available for slender shear panels.  It seems
that Simpson recongnized this and some what centered their product testing
around this issue.  I am not familiar with the Hardy product.

Just for the record what was the aspect ratio of the in situation you
described.

Keith De Lapp


----- Original Message -----
From: Gerard Madden <gmadden(--nospam--at)duquette-eng.com>
To: <seaint(--nospam--at)seaint.org>
Sent: Thursday, November 08, 2001 8:55 PM
Subject: Hardy Panels


> A contractor recently told me of a Hardy Panel/Frame horror story where he
> was forced to remove a raised floor installation of a hardy frame to a
> strongwall raised floor installation. The reason he was told to remove
them
> was related to drift.
>
> Simpson has no ICBO approval for this application while Hardy does. I
> informed him of this and he knew what I was talking about and he stated he
> presented the ICBO report and was stilled forced to remove the Hardy's.
> Anyone else come across this? Also, I don't see how drift could be a
reason
> if one is designing using simplified base shear. This came up when he was
> bidding a job I worked on that called for raised floor Hardy Panels and he
> was concerned about getting screwed.
>
> thanks,
> -Gerard
>
> Gerard Madden, PE
> Design Group Manager
>



******* ****** ******* ******** ******* ******* ******* ***
*   Read list FAQ at: http://www.seaint.org/list_FAQ.asp
* 
*   This email was sent to you via Structural Engineers 
*   Association of Southern California (SEAOSC) server. To 
*   subscribe (no fee) or UnSubscribe, please go to:
*
*   http://www.seaint.org/sealist1.asp
*
*   Questions to seaint-ad(--nospam--at)seaint.org. Remember, any email you 
*   send to the list is public domain and may be re-posted 
*   without your permission. Make sure you visit our web 
*   site at: http://www.seaint.org 
******* ****** ****** ****** ******* ****** ****** ******** 

******* ****** ******* ******** ******* ******* ******* ***
*   Read list FAQ at: http://www.seaint.org/list_FAQ.asp
* 
*   This email was sent to you via Structural Engineers 
*   Association of Southern California (SEAOSC) server. To 
*   subscribe (no fee) or UnSubscribe, please go to:
*
*   http://www.seaint.org/sealist1.asp
*
*   Questions to seaint-ad(--nospam--at)seaint.org. Remember, any email you 
*   send to the list is public domain and may be re-posted 
*   without your permission. Make sure you visit our web 
*   site at: http://www.seaint.org 
******* ****** ****** ****** ******* ****** ****** ********