Jorge,

It is an interesting first-hand information; and a bit sigh of relief to note other top elements got blown off instead of uplifting of the footing!

Thanx for the input.

SYED FAIZ AHMAD; MENGG, MASCE
SENIOR STRUCTURAL ENGINEER
SAUDI OGER LTD
RIYADH, SAUDI ARABIA.



From: "Jorge Naya" <jnaya(--nospam--at)earthlink.net>
Reply-To: "Jorge Naya" <jnaya(--nospam--at)earthlink.net>
To: <syedfaiz23(--nospam--at)hotmail.com>
Subject: SF Uplift
Date: Fri, 9 Nov 2001 12:50:27 -0500

Syed,

In South Florida we have been designing for serious wind
for a while.

Normal usage is SF = DL / Uplift >= 1.50, all using service loads
and ASCE 7 wind (not the ASCE loa combinations),  and accounting
for weight of soil, slab, almost anything that could help.

In many cases the footing becomes an anchor!

Regards,
Jorge Naya, P.E.

P.S. After hurricane Andrew, no footings were seen uplifted,
always something else above failed first.


_________________________________________________________________
Get your FREE download of MSN Explorer at http://explorer.msn.com/intl.asp


******* ****** ******* ******** ******* ******* ******* ***
*   Read list FAQ at: http://www.seaint.org/list_FAQ.asp
* * This email was sent to you via Structural Engineers * Association of Southern California (SEAOSC) server. To * subscribe (no fee) or UnSubscribe, please go to:
*
*   http://www.seaint.org/sealist1.asp
*
* Questions to seaint-ad(--nospam--at)seaint.org. Remember, any email you * send to the list is public domain and may be re-posted * without your permission. Make sure you visit our web * site at: http://www.seaint.org ******* ****** ****** ****** ******* ****** ****** ********