I do not know if it is code.  The rational is that for larger sizes of wood more defects are allowed than for smaller sizes so if  you cut up a piece you well end up with a greater amount of defects per area.  The concept is logical if seldom taken into account.  I would concede the point to the checker.
 
George Richards, P. E.
-----Original Message-----
From: Mark Baker [mailto:shake4bake(--nospam--at)earthlink.net]
Sent: Friday, December 07, 2001 10:21 AM
To: seaint(--nospam--at)seaint.org
Subject: lumber grade reduction

Just received a plan check comment "if you rip a wood member, beam or joist, you have to design it as Grade 3".
 
Is this true? If so, where is the code language to substantiate it?
 
Thanks,
 
Mark