Need a book? Engineering books recommendations...

Return to index: [Subject] [Thread] [Date] [Author]

Retrofit Diaphragm Blocking

[Subject Prev][Subject Next][Thread Prev][Thread Next]
Ok, say you have a plywood diaphragm that was shown and specified to be
blocked (Vmax > 420 plf), but the building is now built, with the roof
shingles installed and gyp board covering the wood truss roof bottom chords
- but no blocking.  The unblocked allowable shear is only 285 plf.

Has anyone had experience retrofitting blocking to a plywood roof from the
underside?  Can an adhesive be used for this?  Intuitively, if the adhesive
can achieve failure of the wood fiber, it should work.  Is there anything
published that can be referred to?

TIA,
Philip J. Caswell, P.E.
St. Paul, MN

******* ****** ******* ******** ******* ******* ******* ***
*   Read list FAQ at: http://www.seaint.org/list_FAQ.asp
* 
*   This email was sent to you via Structural Engineers 
*   Association of Southern California (SEAOSC) server. To 
*   subscribe (no fee) or UnSubscribe, please go to:
*
*   http://www.seaint.org/sealist1.asp
*
*   Questions to seaint-ad(--nospam--at)seaint.org. Remember, any email you 
*   send to the list is public domain and may be re-posted 
*   without your permission. Make sure you visit our web 
*   site at: http://www.seaint.org 
******* ****** ****** ****** ******* ****** ****** ********