Need a book? Engineering books recommendations...

Return to index: [Subject] [Thread] [Date] [Author]

FW: 1997 UBC 1633.2.8.1 (5) 3x requirement in IBC somewhere?

[Subject Prev][Subject Next][Thread Prev][Thread Next]
> Hello:
> 
> 
> The 97 UBC required 3x framing for wood members that are part of a masonry
> wall out-of-plane anchorage system in seismic zone 4.   97 UBC 1633.2.8.1
> (5) says "...wood elements of the wall anchorage system ...shall have a
> minimum net thickness of 2.5 inches."  I have not been able to locate
> where this requirement made it into the IBC.
> 
> Did the requirement go away with the IBC  or is it there somewhere?
> 
> 
> Thanks.
> 
> Scott M Haan P.E.
> Plan Review Engineer
> Building Safety Division 
> Development Services Department
> Municipality of Anchorage
> http://www.muni.org/building
> phone:907-343-8183  
> fax:907-249-7399
> mailto:haansm(--nospam--at)ci.anchorage.ak.us
> 
> 

******* ****** ******* ******** ******* ******* ******* ***