For small spaces, I use 1" thickness, figuring that the grout can be placed
in dry-pack form, compacted with a 3/4" thick 1x.   For large spaces, I use
2" thick, figuring that the dry-pack can be compacted with a 1-1/2" thick
2x.

Nels Roselund
Structural Engineer
South San Gabriel, CA