Re: Crack Control Joints - Unreinforced Slab on Grade

[Subject Prev][Subject Next][Thread Prev][Thread Next]
Assuming there is only foot traffic, that the soil is non-expansive, and
that you are using a 4" slab, I would have sawed joints at 20'x 20' and
use #3 @ 18" each way, in the center of the slab.

Stan Scholl, P.E.
Laguna Beach, CA

******* ****** ******* ******** ******* ******* ******* ***