RE: 3x foundation sills - IBC & UBC, required in FEMA 368?

[Subject Prev][Subject Next][Thread Prev][Thread Next]
Thanks.
 
I've seen laminated doubling studs and having the panels break between them substitute for 3x but I thought the idea was the panels were not being nailed on the same piece.  For a sill plate doubling up does not get around the code language for 3x nominal.  Are you saying people are using doubled 2x as a substitute for 3x sills there?
 
-----Original Message-----
From: Jnapd(--nospam--at)aol.com [mailto:Jnapd(--nospam--at)aol.com]
Sent: Friday, March 29, 2002 2:11 PM
To: seaint(--nospam--at)seaint.org
Subject: Re: 3x foundation sills - IBC & UBC, required in FEMA 368?

Yes it's readly availble here, used all the time.
Using double bottom plate with treated on bottom and connected with 10d's @ 6" staggered.

Joe Venuti

Johnson & Nielsen Associates
Palm Springs,  CA