Davin,

Since drop panels are usually added to increase the punching shear
resistance, I would typically say that no additional reinforcement is
required for the drop panel.  If for some reason the drop panels are being
added for another reason, then some additional reinforcement in the drop
panels might be appropriate, but with out further details, it is not
possible to really say "yes" or "no" to such a situation.

HTH,

Scott
Ypsilanti, MI


On Wed, 3 Jul 2002, Davin Weinhardt wrote:

> Just out of curiosity, how many would say that a
> 4" drop panel below a 9 1/2" two-way slab needs
> reinforcement? What if I added that there is no
> drift issues? If you still say yes, please state
> why (references would be great)!
> 
> Thanks in advance,
> Davin
> 


******* ****** ******* ******** ******* ******* ******* ***