        There is some interesting background to the Canadian position on this
system.

        A few years ago engineers and architects were faced with a large number
of claims relating to failures with the system which at that time was
significantly inferior to what it is today.  As a result, ENCON (the
organization providing insurance for architects and engineers) wrote to all
engineers and architects requesting that they stop using the system.  Period.
Of course there were loud screams of anguish from the suppliers, the loudest
coming from the Canadian Sheet Steel Building Institute (CSSBI), whose counter
proposal led to the present requirements (which also include increased site
inspections relative to what was previously being done).

Regards,

H. Daryl Richardson

"Sprague, Harold O." wrote:

> This topic has been discussed on the list on several occasions.  The Metal
> Lath / Steel Framing Association and the Brick Institute of America both
> predicated their recommendations on the same 222 page Clemson study, but
> they came up with markedly different conclusions.  The MLSFA recommended
> L/360.  The BIA recommended L/600.  They did not want to have their brick
> joints cracked.
>
> In the mean time, the Canadians did their own thing.  The Canada Mortgage
> and Housing Corporation did some very good research.  Re: Technics Steel
> Stud / Brick Veneer Walls, by Trestain and Rousseau, Progressive
> Architecture.  The Canadians went with L/720.  The reference also contains
> some additional design and construction recommendations that are very good.
>
> My personal preference is to infer a 10 year wind with L/720 by designing to
> L/600 for the 50 year wind.  I also go to a G90 stud, and if I am pushed I
> will go to hot rolled channels.
>
> Not to make your problem worse, but your 25 psf sounds light for the corner
> condition.
>
> Read all about it in the references at:
> http://www.masonconf.com/miw/veneer/refandbib.html
>
> Regards,
> Harold O. Sprague
>
> > -----Original Message-----
> > From: richard lewis [SMTP:rlewistx(--nospam--at)juno.com]
> > Sent: Thursday, July 18, 2002 3:15 PM
> > To:   seaint(--nospam--at)seaint.org
> > Subject:      Brick with Metal Stud Backup
> >
> > I am designing a brick wall with a metal stud backup.  The BIA notes
> > recommend the metal stud be sized to support all the wind load with a
> > maximum deflection of h/600.  The building has a few areas with very tall
> > walls.  The worst case unbraced height is about 19 feet.  The component
> > and cladding wind pressure is 25 psf.
> >
> > I have several questions:
> >
> > 1. Should the wind load be the 10 year wind load or the 50 year wind
> > load?  The 50 year wind load blows this out of the water for deflection
> > criteria, although the 10 year is not much better.
> > 2. What have others done as solutions to tall stud walls?  Any
> > suggestions of how to economically reduce the wall height?  Perhaps
> > double studs or something like that?
> >
> > Rich
> >
>
> ******* ****** ******* ******** ******* ******* ******* ***
> *   Read list FAQ at: http://www.seaint.org/list_FAQ.asp
> *
> *   This email was sent to you via Structural Engineers
> *   Association of Southern California (SEAOSC) server. To
> *   subscribe (no fee) or UnSubscribe, please go to:
> *
> *   http://www.seaint.org/sealist1.asp
> *
> *   Questions to seaint-ad(--nospam--at)seaint.org. Remember, any email you
> *   send to the list is public domain and may be re-posted
> *   without your permission. Make sure you visit our web
> *   site at: http://www.seaint.org
> ******* ****** ****** ****** ******* ****** ****** ********


******* ****** ******* ******** ******* ******* ******* ***
*   Read list FAQ at: http://www.seaint.org/list_FAQ.asp
* 
*   This email was sent to you via Structural Engineers 
*   Association of Southern California (SEAOSC) server. To 
*   subscribe (no fee) or UnSubscribe, please go to:
*
*   http://www.seaint.org/sealist1.asp
*
*   Questions to seaint-ad(--nospam--at)seaint.org. Remember, any email you 
*   send to the list is public domain and may be re-posted 
*   without your permission. Make sure you visit our web 
*   site at: http://www.seaint.org 
******* ****** ****** ****** ******* ****** ****** ********