Need a book? Engineering books recommendations...

Return to index: [Subject] [Thread] [Date] [Author]

Eccentric Loading on Spread Footing

[Subject Prev][Subject Next][Thread Prev][Thread Next]
I am checking an AASHTO spread footing design where the eccentric biaxial
loading is high but the resulting bearing pressures are 1/2 the allowable. 

The kern is governing the dimensions of the footing due to AASHTO
4.4.7.1.1.1, last sentence, which mandates the eccentricity be within 1/6 of
the footing dimension in any direction.  

Has anyone found relief for this controlling statement?  Why would AASHTO
give formulae for eccentricities > 1/6 the footing dimension if it is not
allowed? (See Eqn. 4.4.7.1.1.1-6)