Need a book? Engineering books recommendations...

Return to index: [Subject] [Thread] [Date] [Author]

RE: UBC Eq. 30-1

[Subject Prev][Subject Next][Thread Prev][Thread Next]
Ev is only used in non-working stress design. It is a reduction factor
for dead lead and acts Upward. SO combine this term with your DL and
you'll get something smaller than 0.9D in your load combo.

-gerard
Santa Clara, CA

-----Original Message-----
From: RainCat1(--nospam--at)aol.com [mailto:RainCat1(--nospam--at)aol.com] 
Sent: Wednesday, September 11, 2002 1:18 PM
To: seaint(--nospam--at)seaint.org
Subject: UBC Eq. 30-1

In the UBC Eq. 30-1 E=rhoEh + Ev, what is the direction for Ev?
Are we suppose to combine numerically the expressions rhoEh & Ev?
Thanks!

******* ****** ******* ******** ******* ******* ******* ***
*   Read list FAQ at: http://www.seaint.org/list_FAQ.asp
* 
*   This email was sent to you via Structural Engineers 
*   Association of Southern California (SEAOSC) server. To 
*   subscribe (no fee) or UnSubscribe, please go to:
*
*   http://www.seaint.org/sealist1.asp
*
*   Questions to seaint-ad(--nospam--at)seaint.org. Remember, any email you 
*   send to the list is public domain and may be re-posted 
*   without your permission. Make sure you visit our web 
*   site at: http://www.seaint.org 
******* ****** ****** ****** ******* ****** ****** ******** 


******* ****** ******* ******** ******* ******* ******* ***
*   Read list FAQ at: http://www.seaint.org/list_FAQ.asp
* 
*   This email was sent to you via Structural Engineers 
*   Association of Southern California (SEAOSC) server. To 
*   subscribe (no fee) or UnSubscribe, please go to:
*
*   http://www.seaint.org/sealist1.asp
*
*   Questions to seaint-ad(--nospam--at)seaint.org. Remember, any email you 
*   send to the list is public domain and may be re-posted 
*   without your permission. Make sure you visit our web 
*   site at: http://www.seaint.org 
******* ****** ****** ****** ******* ****** ****** ********