RE: Commercial Bldg. - Second Floor Loads

[Subject Prev][Subject Next][Thread Prev][Thread Next]
Office LL is 50 PSF, isn't it?

I believe 100 PSF LL is for exiting which has no partition loads involved.

I usually design for 100 PSF (w/o partition load) because it is greater than
50 PSF + 20 PSF. This way, there is an opportunity to remodel without
regards to where the exit corridor is. Then, of course I use the 10 PSF for
lateral design.

Soooo...my way would be 14 + 100 for the design of the floor framing. 14 +
10 for the mass in the seismic design.

Just my two cents.

Bill Allen, S.E. (CA #2607)



||-----Original Message-----
||From: DRPFLY(--nospam--at)aol.com [mailto:DRPFLY(--nospam--at)aol.com]
||Sent: Wednesday, September 25, 2002 9:33 AM
||To: seaint(--nospam--at)seaint.org
||Subject: Commercial Bldg. - Second Floor Loads
||
||
||Hello all you engineers who design commercial buildings all
||day long.
||
||I am designing the beams for a mezzanine in a commercial
||building and I am
||confused about what loads I should use.
||        Floor DL = 14 psf
||        Floor LL =  100 psf
||        Partitions = 20 psf
||The floor framing is 14" TJL (open-web) at 16" o.c..  I talked to the
||Trus-Joist rep. yesterday and he said he designs the trusses
||using only (14 +
||100) psf (no partition load) because live load and partitions
||cannot occupy
||the same space.  Makes sense to me.  So do I design my beams
||with the same
||load criteria or use (14 + 20 + 100) psf ??  Don't laugh.
||This is serious.
||I usually design one-story residences and it's been a long
||time since my last
||commercial job.
||Plus, I called another engineer in the area and got
||conflicting information.
||
||TIA,
||Denise Poeltler, P.E.
||The Flying Buttress
||
||******* ****** ******* ******** ******* ******* ******* ***
||*   Read list FAQ at: http://www.seaint.org/list_FAQ.asp
||*
||*   This email was sent to you via Structural Engineers
||*   Association of Southern California (SEAOSC) server. To
||*   subscribe (no fee) or UnSubscribe, please go to:
||*
||*   http://www.seaint.org/sealist1.asp
||*
||*   Questions to seaint-ad(--nospam--at)seaint.org. Remember, any email you
||*   send to the list is public domain and may be re-posted
||*   without your permission. Make sure you visit our web
||*   site at: http://www.seaint.org
||******* ****** ****** ****** ******* ****** ****** ********
||


******* ****** ******* ******** ******* ******* ******* ***
*   Read list FAQ at: http://www.seaint.org/list_FAQ.asp
* 
*   This email was sent to you via Structural Engineers 
*   Association of Southern California (SEAOSC) server. To 
*   subscribe (no fee) or UnSubscribe, please go to:
*
*   http://www.seaint.org/sealist1.asp
*
*   Questions to seaint-ad(--nospam--at)seaint.org. Remember, any email you 
*   send to the list is public domain and may be re-posted 
*   without your permission. Make sure you visit our web 
*   site at: http://www.seaint.org 
******* ****** ****** ****** ******* ****** ****** ********