Thanks for all your helpful and contradictory advice.

The commercial building with the new mezzanine is currently owned by  a TV 
station and the architect suggested the 100 PSF to cover all future uses 
including, I guess, moving the partitions.  There are a couple of stairways 
(exit facilities) plus a walkway around part of the mezzanine.  I think using 
a blanket LL = 100 PSF is okay for the all the intended uses.

According to the UBC 1606, partition loads are considered Dead Loads and if 
they are movable I am obligated to include this in the regular floor dead 
loads.  This assumes that partitions are stacked side-by-side the whole 
length and width of the tributary floor area.  Seems a bit heavy-handed to 
me, but I want to do the right thing. 

On the other hand, it seems to me a linear truss can carry LL=100 PSF and DL 
= 14 PSF but not partition load at the same time.

So this is what I'm going to do:

Truss design:  DL = 14 PSF
                      LL =  100 PSF

Floor beams:  DL = 14 + 20 PSF
                      LL = 100 PSF
I think that covers all the bases, don't you?  (Oh no, a sports cliche!)  
Come on Angels! 

Regards, 
Denise Poeltler
The Flying Buttress
Palm Desert, CA

******* ****** ******* ******** ******* ******* ******* ***
*   Read list FAQ at: http://www.seaint.org/list_FAQ.asp
* 
*   This email was sent to you via Structural Engineers 
*   Association of Southern California (SEAOSC) server. To 
*   subscribe (no fee) or UnSubscribe, please go to:
*
*   http://www.seaint.org/sealist1.asp
*
*   Questions to seaint-ad(--nospam--at)seaint.org. Remember, any email you 
*   send to the list is public domain and may be re-posted 
*   without your permission. Make sure you visit our web 
*   site at: http://www.seaint.org 
******* ****** ****** ****** ******* ****** ****** ********