Re: Commercial Bldg. - Second Floor Loads

[Subject Prev][Subject Next][Thread Prev][Thread Next]
Hi Dennis! How are the dogs?
Thanks for helping me with this.  The Trus-joist rep. sent me the calc for 
the TJL floor truss using total dead load of 14 PSF and 100 PSF (100%)  plus 
a code required point load application.  
So here's the deal.
        Floor trusses: DL = 14 psf
                             LL =  100 psf (unreduced) 
        Floor beams:   DL = 14 + 20 psf
                              LL = 80 psf  (reduced)
Do I have it right this time?

Denise Poeltler
The Flying Buttress