RE: Flag Pole Footings.

[Subject Prev][Subject Next][Thread Prev][Thread Next]
You may wish to consider the SEAOC Seismology opinion for cantilever columns, which suggests the use of 
a grade beam between a pair of cantilever columns and has some limitations regarding the percentage of total
shear (by trib area) that should be applied, if you wish to use a reasonable "R" value for the design of the rest of the 
single family occupancy.  This opinon is used in some jurisdictions in California.

It is like having a "restrained" flagpole, but is actually better, since you can control the stiffness of the grade beam, much better than the stiffness of the soil.

J. Diebold, SE



******* ****** ******* ******** ******* ******* ******* ***