Bill is right.  You need to provide that minimum 4d edge distance.  This
minimum is also to prevent a side blowout failure at the head of the bolt
due to the tension load.

Ed Haninger
Fluor Daniel
Aliso Viejo, CA




                                                                                                                   
                    "Bill Polhemus"                                                                                
                    <bill@polhemus.      To:     <seaint(--nospam--at)seaint.org>                                               
                    cc>                                                                                            
                    10/25/02 12:19       cc:                                                                       
                    PM                                                                                             
                    Please respond       Subject:     RE: Design of Anchorage to Concrete                          
                    to seaint                                                                                      
                                                                                                             ..... 
                                                                                                                   




Doesn't matter; the edge distance is still an influence. See ACI 318-02
App. D.
 -----Original Message-----
 From: VerneK(--nospam--at)aol.com [mailto:VerneK(--nospam--at)aol.com]
 Sent: Friday, October 25, 2002 2:06 PM
 To: seaint(--nospam--at)seaint.org
 Subject: Re: Design of Anchorage to Concrete

 The edge distance of 4 diameters is only in the shear section.  I will
 account for
 the pullout loss of shear cone by a reduction factor.





-----------------------------------------------------------------------------------------------------
The information transmitted is intended only for the person
or entity to which it is addressed and may contain confidential
and/or privileged material. If you are not the intended recipient 
of this message you are hereby notified that any use, review,
retransmission, dissemination, distribution, reproduction or any
action taken in reliance upon this message is prohibited. If you 
received this in error, please contact the sender and delete the 
material from any computer.  Any views expressed in this message
are those of the individual sender and may not necessarily reflect 
the views of the company.  
-------------------------------------------------------------------------------------------------------


******* ****** ******* ******** ******* ******* ******* ***
*   Read list FAQ at: http://www.seaint.org/list_FAQ.asp
* 
*   This email was sent to you via Structural Engineers 
*   Association of Southern California (SEAOSC) server. To 
*   subscribe (no fee) or UnSubscribe, please go to:
*
*   http://www.seaint.org/sealist1.asp
*
*   Questions to seaint-ad(--nospam--at)seaint.org. Remember, any email you 
*   send to the list is public domain and may be re-posted 
*   without your permission. Make sure you visit our web 
*   site at: http://www.seaint.org 
******* ****** ****** ****** ******* ****** ****** ********