Re: section 1633.2.9 (3) / masonry veneer

[Subject Prev][Subject Next][Thread Prev][Thread Next]
Paul,

My opinion would be "yes" that is does apply.  Part of the seismic load
from the mass of the wall would have to be carried into the diaphragm to
be taken to the lateral resistance elements, unless the wall is meant to
be a self-supported cantilever wall.  Another way to look at it is to look
at it from a wind type perspective...if there is wind blowing on that
wall, some of that load will react onto the diaphragm that is laterally
supporting the wall.  Same thing with a seismic load.

But then you have to factor in that I am not that familiar with the UBC so
my intepretation may leave some to be desired.

HTH,

Scott
Ypsilanti, MI


On Fri, 28 Feb 2003 PFFEI(--nospam--at)aol.com wrote:

> i have a building with a 4" brick and stone veneer supported on metal studs,
> that are braced to a wood diaphragm building with special steel braced frames
> and special steel moment frames.  the wording of this section of the code is
> unclear as to whether it applies to masonry and concrete shear wall / bearing
> wall buildings or any wood diaphragm building that has masonry walls of any
> sort.  a case could be made that a veneer could have a mass approaching that
> of an 8" concrete wall.  I know the intent of this provision would not apply
> to a building that has a 1" masonry veneer on stucco, but without a limiting
> load case or definition where do you cut off?
>
> if it is some sort of mass based definition, what about buildings  that
> utilize a concrete topping slab on wood diaphragm?
>
> thanks in advance for any thoughts on this issue.
>
> paul franceschi s.e.
>
> ******* ****** ******* ******** ******* ******* ******* ***
> *   Read list FAQ at: http://www.seaint.org/list_FAQ.asp
> *
> *   This email was sent to you via Structural Engineers
> *   Association of Southern California (SEAOSC) server. To
> *   subscribe (no fee) or UnSubscribe, please go to:
> *
> *   http://www.seaint.org/sealist1.asp
> *
> *   Questions to seaint-ad(--nospam--at)seaint.org. Remember, any email you
> *   send to the list is public domain and may be re-posted
> *   without your permission. Make sure you visit our web
> *   site at: http://www.seaint.org
> ******* ****** ****** ****** ******* ****** ****** ********
>


******* ****** ******* ******** ******* ******* ******* ***
*   Read list FAQ at: http://www.seaint.org/list_FAQ.asp
* 
*   This email was sent to you via Structural Engineers 
*   Association of Southern California (SEAOSC) server. To 
*   subscribe (no fee) or UnSubscribe, please go to:
*
*   http://www.seaint.org/sealist1.asp
*
*   Questions to seaint-ad(--nospam--at)seaint.org. Remember, any email you 
*   send to the list is public domain and may be re-posted 
*   without your permission. Make sure you visit our web 
*   site at: http://www.seaint.org 
******* ****** ****** ****** ******* ****** ****** ********