Jonathan,

Footnote 8 is correct.  See ICBOs website for all the UBC errata.

http://www.icbo.org/Code_Talk/Errata/1997-ubc-jan-01.pdf

Thomas Hunt, S.E.
ABS Consulting




"Meyer, Jonathan" <jmeyer(--nospam--at)webbersmith.com>

04/17/2003 06:27 AM
Please respond to seaint

       
        To:        "'seaint(--nospam--at)seaint.org'" <seaint(--nospam--at)seaint.org>
        cc:        
        Subject:        1997 UBC Concrete OMRF in Zone 2A



It has been discovered that different versions of the 1997 UBC have different footnotes for the same item in Table 16-N. One version (seventh printing) references footnote 8 which precludes the use of concrete OMRF in Zones 2A, 2B, 3 & 4 and the other version (CD version 1.2) references footnote 7 which relates to the total height of the building including cantilevered columns. It seems that footnote 8 is the correct one, but does anyone know which is correct?