Re: Concrete disintegration

[Subject Prev][Subject Next][Thread Prev][Thread Next]

I am back again !

Transit mixers often use "retarders" to inhibit early set during hauling. An indiscriminate over dosage of the same often ends up in the problem now faced by you.

So, my advise to you is to: check if some non-professional element of over dosage was really made.

Regards to all,

Syed Faiz Ahmad; MEngg, M. ASCE

Senior Structural Engineer

Saudi Oger Ltd

Riyadh, Saudi Arabia.

>From: Roger Turk <73527.1356(--nospam--at)compuserve.com>
>Reply-To:
>To: seaint(--nospam--at)seaint.org
>Subject: Concrete disintegration
>Date: Wed, 23 Apr 2003 17:07:09 -0400
>
>Mike,
>
>Please post what you find out as I'm sure that everyone would like to know.
>
>In the meantime, I'll throw out a couple of things for you to consider:
>
>Do the trucks have aluminum drums, fins or chutes? If the concrete was
>pumped, did the pump line have an aluminum liner or was aluminum? Aluminum
>and concrete do not get along well at all.
>
>Sugar will prevent concrete from setting up, but that would have prevented
>the test cylinders to set up also. (Not a delayed reaction that I am aware
>of.)
>
>Were any admixtures used and were they used in the proper amount? I think
>that there was a recent article in ENR where about 10 times the recommended
>amount of an admixture was added to concrete and caused problems.
>
>HTH
>
>Good Luck!
>
>A. Roger Turk, P.E.(Structural)
>Tucson, Arizona
>
>Mike Livingston wrote:
>
>. > Yesterday I told my kids I crushed concrete with my bare hands. It was
>. > less funny for the homeowners though. I was called out to look at some
>. > homes where the basement walls and foundations were spalling, slumping,
>. > and just plain crumbling away. The homes are many miles away from each
>. > other with the concrete supplier being the common factor. Test cylinders
>. > from the same batch were recently tested with about 1/4 of the strength
>. > they had before. We're going to take core samples, do a chemical
>. > analysis, and replace the foundation, but I'm curious as to what you
>. > think the supplier put into his concrete to have such devastating results
>. > a few months later? (Seems salt instead of sand might do the trick...)
>. > Does anyone have any reference materials they can aim me at?
>
>. > Thanks,
>
>. > Mike Livingston, SE, CE, P.Eng
>
>******* ****** ******* ******** ******* ******* ******* ***
>* Read list FAQ at: http://www.seaint.org/list_FAQ.asp
>*
>* This email was sent to you via Structural Engineers
>* Association of Southern California (SEAOSC) server. To
>* subscribe (no fee) or UnSubscribe, please go to:
>*
>* http://www.seaint.org/sealist1.asp
>*
>* Questions to seaint-ad(--nospam--at)seaint.org. Remember, any email you
>* send to the list is public domain and may be re-posted
>* without your permission. Make sure you visit our web
>* site at: http://www.seaint.org
>******* ****** ****** ****** ******* ****** ****** ********


Add photos to your messages with MSN 8. Get 2 months FREE*. ******* ****** ******* ******** ******* ******* ******* *** * Read list FAQ at: http://www.seaint.org/list_FAQ.asp * * This email was sent to you via Structural Engineers * Association of Southern California (SEAOSC) server. To * subscribe (no fee) or UnSubscribe, please go to: * * http://www.seaint.org/sealist1.asp * * Questions to seaint-ad(--nospam--at)seaint.org. Remember, any email you * send to the list is public domain and may be re-posted * without your permission. Make sure you visit our web * site at: http://www.seaint.org ******* ****** ****** ****** ******* ****** ****** ********