Robert,

In the past I have sent samples of wood off to be analyzed.  You only
need a very small sample.  I believe it was to the Forest Product Lab. 
I'm not sure about that.  I haven't done it in several years and the
files for the projects I did do it for are at another engineering
business.  I recall that the FPL would do up to 5 samples a year free of
charge.  They just give you the species of wood, not the allowable
stresses, etc.  You have to come up with those based on your engineering
judgement.  You have to wait on them though, it is not a speedy process. 
I would say that you also need to use your judgement about the damage to
the wood verses reduction in stress.  Hey, that's why your getting the
big bucks!  I recall a book by ASCE written at least 20 years ago about
restoring old wood structures.  You may look for a copy of it.  Again, it
is at the former engineering firm so I don't know the exact title.  Is
your project big enough to warrant calling in a professional grader to
give you guidance on the grading of the wood in place?  

Rich



On Fri, 25 Apr 2003 08:53:05 -0400 "Robert Rogers" <RRogers(--nospam--at)lorwil.com>
writes:
> 
> Did I mention the building was constructed around 1918 ?....would 
> you
> still use the same approach ?
> 
> Additionally, how would you take into account possible weathering /
> exposure damage ?
> 
> Robert
> 
> -----Original Message-----
> From: Roger Turk [mailto:73527.1356(--nospam--at)compuserve.com] 
> Sent: Friday, April 25, 2003 8:37 AM
> To: seaint(--nospam--at)seaint.org
> Subject: Historic Wood Structure; How to Determin
> 
> 
> Robert,
> 
> Prior to 1970's, the lowest grade of structural wood was 
> "Construction 
> Grade."  Comparing the visual grading rules of 1960's "Construction
> Grade" to 
> today's grading rules, these are equivalent to today's No. 1 grade,
> therefor, 
> I would use the allowable stresses for today's No. 1 Grade to 
> evaluate
> the 
> structural capacities of the existing members.  (Also, I believe 
> that
> the 
> UCBC states that No. 1 grade stresses be used.)
> 
> HTH
> 
> A. Roger Turk, P.E.(Structural)
> Tucson, Arizona
> 
> Robert Rogers wrote:
> 
> . > A question for all of my colleagues.......looking at an 
> existing
> brick . > masonry shell & interior wood joist, timber girder, 
> timber
> column . > 4-story structure......roof was off top of structure for 
> 3~4
> year time . > frame and some water damage has occurred.  Joists are 
> 3x14
> @ 14" o.c. . > and timber girders are range from 10x12 to 14 x16 and 
> the
> columns range . > from 10x10 to 14x14.  Floor dead loads are 
> increasing
> but live load is . > decreasing (used to be an old light-industrial
> building; being converted . > to "lofts"; loads added to roof).  
> Joists
> span ~19 feet, girders span . > ~14 ft. and column height ~12-13 
> feet.
>  
> . > Material testing company performed visual / sounding of wood 
> members
> and . > provided recommendation on replacement of specific members 
> but
> refused . > to provide any allowable stresses for the wood members.
> Material . > testing company provided species type but would not
> identify grade . > (thereby "locking-in" allowable stresses per NDS
> supplement for use in . > structural analysis).
>  
> . > How would any of you approach this situation to try and get a 
> handle
> on . > the amount of strength of the existing wood joists, wood 
> girders,
> and . > wood columns (i.e, pin-down the allowable wood stresses) ?  
> I've
> spoke . > to a few "experts" and have their 
> recommendation......what
> would the . > everyday structural practitioner do ?
>  
> . > Robert Rogers, PE
> 
> 
> ******* ****** ******* ******** ******* ******* ******* ***
> *   Read list FAQ at: http://www.seaint.org/list_FAQ.asp
> * 
> *   This email was sent to you via Structural Engineers 
> *   Association of Southern California (SEAOSC) server. To 
> *   subscribe (no fee) or UnSubscribe, please go to:
> *
> *   http://www.seaint.org/sealist1.asp
> *
> *   Questions to seaint-ad(--nospam--at)seaint.org. Remember, any email you 
> *   send to the list is public domain and may be re-posted 
> *   without your permission. Make sure you visit our web 
> *   site at: http://www.seaint.org 
> ******* ****** ****** ****** ******* ****** ****** ******** 
> 
> 

________________________________________________________________
The best thing to hit the internet in years - Juno SpeedBand!
Surf the web up to FIVE TIMES FASTER!
Only $14.95/ month - visit www.juno.com to sign up today!

******* ****** ******* ******** ******* ******* ******* ***
*   Read list FAQ at: http://www.seaint.org/list_FAQ.asp
* 
*   This email was sent to you via Structural Engineers 
*   Association of Southern California (SEAOSC) server. To 
*   subscribe (no fee) or UnSubscribe, please go to:
*
*   http://www.seaint.org/sealist1.asp
*
*   Questions to seaint-ad(--nospam--at)seaint.org. Remember, any email you 
*   send to the list is public domain and may be re-posted 
*   without your permission. Make sure you visit our web 
*   site at: http://www.seaint.org 
******* ****** ****** ****** ******* ****** ****** ********