RE: Braced Frame Cladding

[Subject Prev][Subject Next][Thread Prev][Thread Next]
Are you the building designer, the design-build cladding contractor, or
someone else in the design team? Usually in CA the cladding system is
design build and the structural engineer will give suggestive details on
the methods of supporting the cladding.

The way I have done cladding panels (steel framing supporting limestone
cladding), is to use gravity bearing supports at the top of the panel on
the spandrel beams or columns. At the bottom, I would have wind/seismic
restraints for out of plane loads. The in-plane supports depend on your
system. Sometimes racking/rocking is okay and sometimes not - it's been
about 8 years since I did this type of work and I wasn't high enough up
in the food chain to determine when this was appropriate - I'm sure it
has to do with the window system. You connection at the top and bottom
for in-plane load will determine this behavior.

Issues with slotting holes are based on collision with the structure and
adjacent panels that would damage the cladding or create falling
hazards. If you have Seismic Design Manual Vol II from ICBO, I believe
there are some examples there and maybe some details. The joint sizes
and caulk type may be limiting factors.

I wouldn't worry too much about the cladding taking load out of a
collector beam. I also would avoid field welding as much as possible.
Usually there are embeds in the floor that allow you to mount your
panels. You need leveling devices to get the thing in the right place,
and the use of bolted connections allow for these adjustments.

HTH
-gerard
Santa Clara, CA

-----Original Message-----
From: Seth W. Cutler [mailto:seth(--nospam--at)rlmorrisonengr.com] 
Sent: Friday, May 09, 2003 9:06 AM
To: seaint(--nospam--at)seaint.org
Subject: Braced Frame Cladding

I'm working on a 3 story steel braced frame building with 5 1/2" conc. 
panels as cladding on some parts of the building.  What type of
connections 
should I use to attach the panels to the structural steel?  If I weld
the 
panels directly to the columns and collector beams then won't that be 
stiffer and load the panels rather than the braces?

This is the first building I've had to deal with cladding issues like
this 
and was hoping you guys might have some advice / input.

Some ideas I've had are only attaching the cladding to the horizontal 
perimeter beams with an angle welded to the panel and then bolted to the

beam with a slotted hole to allow the frame to move horizontally.  Does 
this create other issues?


Seth W. Cutler
R. L. Morrison Engineering Co. 


******* ****** ******* ******** ******* ******* ******* ***
*   Read list FAQ at: http://www.seaint.org/list_FAQ.asp
* 
*   This email was sent to you via Structural Engineers 
*   Association of Southern California (SEAOSC) server. To 
*   subscribe (no fee) or UnSubscribe, please go to:
*
*   http://www.seaint.org/sealist1.asp
*
*   Questions to seaint-ad(--nospam--at)seaint.org. Remember, any email you 
*   send to the list is public domain and may be re-posted 
*   without your permission. Make sure you visit our web 
*   site at: http://www.seaint.org 
******* ****** ****** ****** ******* ****** ****** ******** 


******* ****** ******* ******** ******* ******* ******* ***
*   Read list FAQ at: http://www.seaint.org/list_FAQ.asp
* 
*   This email was sent to you via Structural Engineers 
*   Association of Southern California (SEAOSC) server. To 
*   subscribe (no fee) or UnSubscribe, please go to:
*
*   http://www.seaint.org/sealist1.asp
*
*   Questions to seaint-ad(--nospam--at)seaint.org. Remember, any email you 
*   send to the list is public domain and may be re-posted 
*   without your permission. Make sure you visit our web 
*   site at: http://www.seaint.org 
******* ****** ****** ****** ******* ****** ****** ********