Need a book? Engineering books recommendations...

Return to index: [Subject] [Thread] [Date] [Author]

RE: last sheet pile question

[Subject Prev][Subject Next][Thread Prev][Thread Next]
Title: RE: last sheet pile question

Depends on the usage of the bulkhead.  Exposed concrete cap next to a walkway or building foundation you probably want something a little more stringent than 2H/240. 

D. Matthew Stuart, P.E., S.E., P.Eng.
Senior Project Manager
Schoor DePalma Engineers and Consultants
Manalapan Structural Department
200 State Highway Nine
Manalapan, NJ 07726
732-577-9000 (Ext. 1275)
908-309-8657 (Cell)
732 -431-9428 (Fax)
mstuart(--nospam--at)schoordepalma.com

-----Original Message-----
From: Gary [mailto:garyd(--nospam--at)structuralconsulting.com]
Sent: Thursday, May 15, 2003 3:26 PM
To: SEAINT(--nospam--at)SEAINT.ORG
Subject: last sheet pile question

Is there a standard deflection limit for sheet piles?  What do all you
experienced sheet pile folks use as a rule.  Particularly in a cantilever
situation.  I'm planning on using 2 x the excavation depth / 240.