I am trying to attach a vertical stiffener to the thin wall (12 ga) of a 22' dia silo, 50' above the ground. The stiffener is a 1/4" thick double angle carrying a vertical load of 10k to the silo wall by shear through the fastener. Access to the interior is undesirable, as is welding. I am specifying Huck BOM (Blind Oversize Mechanical) Fasteners : ( http://www.huck.com/industrial/fasteners/med_hvy_duty_blindrivets/BOM/bom_intro.html ). These are very similar to a blind rivet and are primarily used in mechanical or transportation (rail car/truck body) applications. I know of no situations where these have been used in building structure applications.

Has anyone experience with these fasteners - are they acceptable in this application? I would feel better with a bolt with ASTM specs and resistance values for backup.

Is it acceptable to design as a bearing bolt. They appear to work very well at compressing the attached components together and hence work as a slip-critical connection, but codes only make reference to A325 or A490 bolts for friction type connections.

Don Vickers





******* ****** ******* ******** ******* ******* ******* ***
*   Read list FAQ at: http://www.seaint.org/list_FAQ.asp
* * This email was sent to you via Structural Engineers * Association of Southern California (SEAOSC) server. To * subscribe (no fee) or UnSubscribe, please go to:
*
*   http://www.seaint.org/sealist1.asp
*
* Questions to seaint-ad(--nospam--at)seaint.org. Remember, any email you * send to the list is public domain and may be re-posted * without your permission. Make sure you visit our web * site at: http://www.seaint.org ******* ****** ****** ****** ******* ****** ****** ********