Need a book? Engineering books recommendations...

Return to index: [Subject] [Thread] [Date] [Author]

RE: Galvanized Rebar

[Subject Prev][Subject Next][Thread Prev][Thread Next]
Instead of galvanized rebars, you might want to consider epoxy-coated
rebars. We have been using epoxy-coated reinforcement for bridge concrete
slab. You need to increase rebar development length or splice length by 15%
if epoxy-coated reinforcement is used.



******* ****** ******* ******** ******* ******* ******* ***