My firm is located in an area where every building ends up in Design
Category "D". We typically try to exhaust all options before using
moment frames because of the IMF or SMF requirement for this Design
Category.

Every now and then we will have a scenario where we want to split a
building into two separate structures (expansion joint) due to building
geometry, inadequate diaphragm strength, re-entrant corners, etc. 

Which leads me to my question. When both or even one of these structures
uses IMF or SMF the lateral deflections become a huge issue with regard
to expansion joints. 

Are expansion joints typically sized for inelastic displacements (i.e.
using cd * elastic displacements)? 

Example:
50 foot tall buidling(s)
building one displacement=2" w/ cd=5.5 yields delta=11
building two displacement=2" w/ cd=5.5 yields dela=11
per IBC building separation=sqrt((11^2)+(11)^2)=15.55


How do you deal with an expansion joint this large? Floors? Wall and
Windows?

Any thoughts or experiences would be greatly appreciated


******* ****** ******* ******** ******* ******* ******* ***
*   Read list FAQ at: http://www.seaint.org/list_FAQ.asp
*
*   This email was sent to you via Structural Engineers
*   Association of Southern California (SEAOSC) server. To
*   subscribe (no fee) or UnSubscribe, please go to:
*
*   http://www.seaint.org/sealist1.asp
*
*   Questions to seaint-ad(--nospam--at)seaint.org. Remember, any email you
*   send to the list is public domain and may be re-posted
*   without your permission. Make sure you visit our web
*   site at: http://www.seaint.org
******* ****** ****** ****** ******* ****** ****** ********