RE: Lateral Deflection of Stucco

[Subject Prev][Subject Next][Thread Prev][Thread Next]
As a board member of the Steel Framing Alliance in California, there are
current efforts being made for funding the research for cyclic load testing
the capacity of standard 3 coat stucco veneer that is attached to cold
formed steel studs. As information becomes available it will become public
information.
Thanks,
Jim L. Chatterley PE
Composite Framing Systems, Inc.
2723 Currier Ave.
Simi Valley, California, 93065
805-520-3666, Fax 805-583-1434
www.compositeframingsystems.com

-----Original Message-----
From: richard lewis [mailto:rlewistx(--nospam--at)juno.com]
Sent: Tuesday, April 06, 2004 12:49 PM
To: seaint(--nospam--at)seaint.org
Subject: Lateral Deflection of Stucco


BIA has established a lateral deflection of metal studs supporting a
brick veneer of H/600.  Is there a recommended lateral deflection of
metal studs that supports a stucco finish?

Thanks.

Rich

________________________________________________________________
The best thing to hit the Internet in years - Juno SpeedBand!
Surf the Web up to FIVE TIMES FASTER!
Only $14.95/ month - visit www.juno.com to sign up today!

******* ****** ******* ******** ******* ******* ******* ***
*   Read list FAQ at: http://www.seaint.org/list_FAQ.asp
*
*   This email was sent to you via Structural Engineers
*   Association of Southern California (SEAOSC) server. To
*   subscribe (no fee) or UnSubscribe, please go to:
*
*   http://www.seaint.org/sealist1.asp
*
*   Questions to seaint-ad(--nospam--at)seaint.org. Remember, any email you
*   send to the list is public domain and may be re-posted
*   without your permission. Make sure you visit our web
*   site at: http://www.seaint.org
******* ****** ****** ****** ******* ****** ****** ********


******* ****** ******* ******** ******* ******* ******* ***
*   Read list FAQ at: http://www.seaint.org/list_FAQ.asp
* 
*   This email was sent to you via Structural Engineers 
*   Association of Southern California (SEAOSC) server. To 
*   subscribe (no fee) or UnSubscribe, please go to:
*
*   http://www.seaint.org/sealist1.asp
*
*   Questions to seaint-ad(--nospam--at)seaint.org. Remember, any email you 
*   send to the list is public domain and may be re-posted 
*   without your permission. Make sure you visit our web 
*   site at: http://www.seaint.org 
******* ****** ****** ****** ******* ****** ****** ********